Products Category
+ pH meter
Details
Product #: 09135=A=0011
pH and ORP (redox) measurement
Universal transmitter (2 high impedance inputs): works with combined and simple
pH electrode, reference electrodes, antimony electrodes, ORP (redox) electrodes.
Large choice of calibration methods:
- automatic determination of buffer solution values
- manual set-up of process pH values, offset and slope
specifications of the electrodes
Wide choice of temperature compensation algorithms:
- according the Nernst equation
- user-programmable coefficient
- non-linear for ultrapure water
- non-linear for process water
Autodiagnostic of the measurement loop with pH and reference electrode impedance control.
Units available in pH and mV.
Integrated controller: frequency mode, pulse modes, combined, bidirectional proportional
function.
Electrode cleaning feature drived by configurable output relay.
POLYMETRON 9135 pH Transmitter
Product #: 09135=A=0011
pH and ORP (redox) measurement
Universal transmitter (2 high impedance inputs): works with combined and simple
pH electrode, reference electrodes, antimony electrodes, ORP (redox) electrodes.
Large choice of calibration methods:
- automatic determination of buffer solution values
- manual set-up of process pH values, offset and slope
specifications of the electrodes
Wide choice of temperature compensation algorithms:
- according the Nernst equation
- user-programmable coefficient
- non-linear for ultrapure water
- non-linear for process water
Autodiagnostic of the measurement loop with pH and reference electrode impedance control.
Units available in pH and mV.
Integrated controller: frequency mode, pulse modes, combined, bidirectional proportional
function.
Electrode cleaning feature drived by configurable output relay.
9135 ph service sparts
factory code
09135=A=0000
|
9135 pH/ORP transmitter
|
09135=A=0004
|
9135 pH/ORP transmitter with 4-relay board
|
09135=A=0011
|
9135 pH/ORP transmitter with RS485 board
|
09135=A=0012
|
9135 pH/ORP transmitter with Profibus DP
|
09135=A=0015
|
9135 pH/ORP transmitter with 4-relay and RS485 boards
|
09135=A=0016
|
9135 pH/ORP transmitter with 4-relay and Profibus DP
|
09135=A=0020
|
9135 pH/ORP low voltage transmitter (24 V)
|
09135=A=0024
|
9135 pH/ORP low voltage transmitter (24V) with 4-relay board
|
09135=A=0032
|
9135 pH/ORP low voltage transmitter (24V) with Profibus DP
|
09135=A=0035
|
9135 pH/ORP low voltage transmitter (24V) with 4-relay and RS485 boards
|
09135=A=0036
|
9135 pH/ORP low voltage transmitter (24V) with 4-relay board and Profibus DP
|
09135=A=0501
|
Equipped shield plate with earth terminal and fixing system for pH transmitter (9135)
|
09135=A=0521
|
Equipped shield plate with earth terminal and fixing system for pH low voltage transmitter (9135)
|
09135=A=1500
|
pH/ORP Measuring board
|
09135=A=3000
|
9135 pH/ORP transmitter tropicalised
|
09135=A=3004
|
9135 pH/ORP transmitter with 4-relay board tropicalised
|
09135=A=6200
|
9135 Software, specific for CPU-ph1(09125=A=1000), transmitter bought before Feb04
|
09135=A=6210
|
Replacement kit with a 91XX CPU board programmed with standard pH firmware, shieldplate and mounting instructions.
|
09135=T=0000
|
9135 transmitter test certificate
|
Z09125=A=1002 |
09125=A=1002 |
Z09135=A=0501 |
Z09135=A=1501 |
Z09135=A=6210 |
Z09135=A=6211 |
Z09135=A=8030 |