hach polymetron 9245 Single Channel On-Line Sodium Analyzer
  
Details
 
9245 Single Channel On-Line Sodium Analyzer (0 to 10,000 ppb) with Enclosure, Universal

9245 Sodium Analyzer


Z09240=A=0004
Z09240=A=0123
Z09240=A=0320
Z09240=A=0510
Z09240=A=0700
Z09240=A=1001
Z09240=A=1002
Z09240=A=1003
Z09240=A=1004
Z09240=A=1500
Z09240=A=5301
Z09240=A=7170
Z09240=A=8000
Z09240=A=8010
Z09240=A=8020
Z09240=A=8305
Z09240=A=8315
Z09240=A=9110
Z09240=A=9120
Z09240=A=9171
Z09240=A=9172
Z09240=A=9200
Z09240=A=9201
Z09240=A=9300
Z09240=A=9510
Z09240=A=9840
Z09240=C=0256
Z09240=C=0257
Z09240=C=0258
Z09240=C=0259
Z09240=C=0310
Z09240=C=0320
Z09245=A=0000
Z09245=A=0001
Z09245=A=0010
Z09245=A=0011
Z09245=A=0020
Z09245=A=0021
Z09245=A=0100
Z09245=A=0101
Z09245=A=0110
Z09245=A=0111
Z09245=A=0120
Z09245=A=0121
Z09245=A=1000
Z09245=A=1001
Z09245=A=1010
Z09245=A=1011
Z09245=A=1020
Z09245=A=1021
Z09245=A=1100
Z09245=A=1101
Z09245=A=1110
Z09245=A=1111
Z09245=A=1120
Z09245=A=1121
Z09245=A=8300
Z09245=A=8310
Z09245=A=8315
Z09245=A=9100

Analyzer has automatic reactivation ensures optimum response time and performance; no acid etching required! 100 days between reagent changes. Includes US fittings kit, 3M KCl, 10 ppm sodium standard, Diisopropylamine (DIPA), and Sodium Nitrate. Available in US and Canada only.

  • Automatic Electrode Reactivation for Optimum Operation and Response Time
  • Easy to Install, Operate, Calibrate, and Maintain
  • Adaptable to a Variety of Conditions
  • Lower Detection Limit of 0.01 ppb
  • 4-20 mA Outputs and Digital Communication Options
  • Automatic Electrode Reactivation for Optimum Operation and Response Time

    To maintain optimum response time, even in systems of continuous low sodium concentration, the analyzer automatically reactivates the electrode using non-hazardous chemicals.

    Easy to Install, Operate, Calibrate, and Maintain

    The 9245 Sodium Analyzer installs easily; it requires only power and sample connections. Clear step-by-step instructions are given by the analyzer to simplify operations such as instrument start-up, long-term stand-by, and reagent replenishment. Low ppb sodium solutions for calibration can be difficult to prepare so the 9245 analyzer is equipped with a fully automated calibration system that uses 10 ppm samples and follows a multiple step calibration cycle to accurately calibrate the analyzer. Normal maintenance consists of replenishment of the calibration solution reagents and electrolyte, typically every 100 days, and annual replacement of the reagent tube.

    Adaptable to a Variety of Conditions

    The analyzer is fitted with a quick-loop valve, a constant head vessel, and minimum sample flow detection to allow for variations in sample pressure, flow, and distance from the analyzer to the fresh-sample point. Grab sample can be obtained for manual calibration, accuracy verification, and measurement of one-off process samples after which, the unit returns automatically to on-line monitoring.

    Lower Detection Limit of 0.01 ppb

    With a detection limit of 0.01 ppb and a range of 0 to 10,000 ppb, the 9245 Sodium Analyzer is ideally suited for monitoring sodium in demineralized water, boiler feed, condensate, and all parts of the steam/water cycle.

    4-20 mA Outputs and Digital Communication Options

    Four sets of isolated analog outputs can be configured in 4-20 mA with three outputs assigned to sample concentration or temperature readings and the fourth reporting electrode live signal, including calibration and grab sample. Additional digital communication is available with JBUS/MODBUS or Profibus DP.

    9245 sodium analyzer, us fittings kit, 3M KCl solution, 10ppm sodium standard, DIPA reagent, Sodium nitrate solution, and Hach manual.

     Specifications

     

    Accuracy:± 0.1 ppb or ±5% of reading, whichever is greater
    Accuracy 2:Cationic application: ± 2 ppb or 5 % of reading, whichever is greater
    Ambient Temperature:5 to 50 °C (41 to 122 °F)
    Communication Capabilities:Standard (4x 4-20 mA outputs)
    Lower Limit of Detection (LOD):0.01 ppb
    Measurement Range 2:0 to 200 ppm with Cation-kit option
    Mounting:Wall mount enclosure
    Panel Dimensions:x x
    Range:0 to 10000 ppb freely programmable
    Repeatability:< 0.02 ppb or 1.5 % of reading, whichever is greater, within 10ºC variation

     

    Response Time:1 cycle, minimum 10 minutes (t=90%)