Hach Polymetron 9610sc Silica Analyzer NEW
  
Details
 
KTO: 9610sc SILICA, 6CH/AC/US, CHEM

9610.KTO.S0.A1U
9610.KTO.S0.A2U
9610.KTO.S0.A4U
9610.KTO.S0.A6U
9610.KTO.S0.D1U
9610.KTO.S0.D2U
9610.KTO.S0.D4U
9610.KTO.S0.D6U
9610.S0.A1U
9610SWAP4U
9610SWAP6U
9611.KTO.PH.A1U
9611.KTO.PH.A2U
9611.KTO.PH.A4U
9611.KTO.PH.D1U
9611.KTO.PH.D2U
9611.KTO.PH.D4U
9611.KTO.PL.A1U
9611.KTO.PL.A2U
9611.KTO.PL.A4U
9611.KTO.PL.D1U
9611.KTO.PL.D2U
9611.KTO.PL.D4U

90 Days of Continuous Run Time

Only two liters of reagent are required for the analyzer to perform unattended for up to 90 days; twice as long as the Series 5000.

Save Time on Maintenance

The industry's only pressurized reagent delivery system eliminates the frequent maintenance associated with pumps.

Avoid Downtime

Predictive diagnostic tools, including Hach's proprietary Prognosys technology, warning LEDs, and high-visibility notification screens let you avoid unplanned downtime.

Clean, Fast and Easy Reagent Change

No more dripping reagents on the instrument, the floor, or your clothing while fumbling with tubes and straws. Simply match the color-coded cap to the sealed reagent bottle and twist gently.

Verify Easily with Hach Lab Products So You Don't Waste Time Second-guessing

Grab Sample In and Out features allow quick analysis of a grab sample poured into the analyzer, and facilitate taking a sample out of the analyzer to verify in a lab test.
 

 Specifications

 

Accuracy:0–500 µg/L: ±1% or ±1 µg/L of reading, whichever is greater; 500–5000 µg/L: ±5% 
(Tested with Hach reagents)
Alarm:Four relays output; type: not powered SPDT relays, each rated at
5 A resistive, 240 VAC maximum
Connection: 18 to 14 AWG wire, 18 AWG stranded recommended
Certifications:CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000 )
KC (EN 61326-1: 2006)
C-tick (EN 61326-1: 2006)
cETLus (UL 61010-1: 2012; NEMA 250: 2003; CSA C22.2 No 61010-1: 2012)
Controller Compatibility:sc200, sc1000
Dimensions (H x W X D):804 mm x 452 mm x 360 mm
Enclosure Rating:NEMA 4X/IP66
Fitting type:Sample line and sample bypass drain: 6 mm (¼-in.)
Air purge inlet: 6 mm (¼-in.) Chemical and case drains: 9.5 mm (3/8-in.)
Grab Sample:Grab Sample In and Grab Sample Out capability
Light Source:Class 1M LED (light emitting diode) with a peak
wavelength of 810 nm
Lower Limit of Detection (LOD):0.5 µg/L

Measuring Principle:Colorimetric
Mounting:Wall, panel or table
Number of Channels:1, 2, 4, 6; 1
Operating Humidity:5 to 95 % non-condensing (indoor use only)
Operating Temperature Range:5 to 45 °C (41 - 113 °F)
Output:4 to 20 mA
Parameter:Silica
Pollution Degree:2/II
Power Requirements (Voltage):100 - 240 VAC
Protection Class:I
Range:0 to 5000 µg/L as SiO2
Reagent Consumption:2 L of each reagent every 90 days with 15 minute cycle time
Relays:Four; type: not powered SPDT relays, each rated at 5 A resistive, 240 VAC maximum
Repeatability:± 0.5 µg/L or ± 1 % of reading, whichever is greater
Response Time:Typically, 9.5 minutes at 25 °C (77 °F); changes with temperature
Sample Flow Rate:55 to 300 mL/min
Sample Pressure:2 to 87 psi (to Preset Pressure Regulator)
Sample Temperature:5 to 50 °C (41 - 122 °F)
Storage Conditions:-20 to 60 °C (-4 - 140 °F)
Weight:44.09 lbs. (20 kg) (45 lb) without reagents and standards, 36.3 kg (80 lb) with reagents

Parameter/Range/Reagent Information

Silica Method Range Reagent Set(s) USEPA Compliant?
  Silicomolybdate/Heteropoly Blue 0.00 - 5,000 µg/L View