1200℃ single/double temperature zone CVD system
1, a double temperature zone furnace body
System name: 1200℃ double temperature zone CVD system
Flow control section
Number of gas paths: 3 quality gas control (the number of gas paths can be selected according to specific needs)
Flow meter: HORIBA METRON (Sino-Japanese joint venture brand)
Flow range: Standard nitrogen calibration 0-500SCCN (can be customized according to customer needs)
Accuracy: ±1%F.S
Response time: 1sec
Operating temperature: 5-450℃
Working pressure: Intake pressure 0.05-0.3Mpa(surface pressure)
System connection: KF quick connection bellows, high vacuum manual flapper valve and digital display vacuum measuring instrument
Vacuum control section
Imported vacuum gauge: INFICON vacuum gauge PCG554
Vacuum gauge range: 5 x 10-5... 1500 (3.8 x 10-5... 1125) (millibar)
High vacuum system pump: pumping speed 6L/S, limit vacuum 3*10-1Pa;
Molecular pump: pumping speed 1200L/S, limit vacuum 5*10-6Pa
Vacuum degree range: 10-1Pa ~ 10-3Pa
Control mode: automatic control
Vacuum gauge: thermocouple gauge/ionization gauge